- 200 Watts of battery analyzer power delivered through four independent channels by the click of a mouse on your Windows PC
- Full speed USB 2.0 interface that supports more than 100 battery analyzers and over 400 channels simultaneously
- Microsoft Windows interface with integrated Access database support
for battery management, analyzer configuration and test results
- Graphical charting of data with zoom and pan features for easy viewing of test results and identifying battery performance and problems
- Services all rechargeable battery chemistries up to 36 Volts and up
to 100 Amp
hour in size

- Each channel has internal non-volatile memory for saving test results of 64 service records
- Data point recording of voltage, current and temperature at every 0.5%
rated capacity increment for up to 224 points or 112% maximum
- Battery test data is automatically downloaded and organized into Access database filing system
according to each battery unique serial number
- Smart battery SMBus read capability on each channel
- High speed data logging and pulse discharge loading to simulate
variable loads on battery performance
- Each channel provides for voltmeter gain calibration as a function
of current to accommodate long test lead connections
- Each channel provides for entry of nominal thermistor resistance
values from 1-100k and associated polynomial factors A, B, C, D
- Switch-mode power supply technology converts power from channels on discharge into power used for channels on charge
- World wide AC input power factor corrected power supply operates from 90 - 260 VAC
- Service records are time stamped with start date, start time, and elapsed time
of service
- Internal real time clock keeps time when PC is unavailable
- Test records can be saved as text files and imported into Excel or other spreadsheet software for custom presentation and reporting

- Charge - Charges the battery
- Discharge - Discharges the battery
- Life Cycle - Performs repeated discharge/charge cycles on the battery
until capacity falls below percent target or up to 10k cycles
- Ohm Test - Charges and then discharges the battery while recording
the voltage and internal resistance in milli-Ohms for every 0.5% rated
capacity
- Prime - New batteries and batteries from
storage are cycled to achieve normal function
- Quick Test - Determines the approximate condition of
a battery within 10-60 minutes, maximum 2 hours
- Recondition - A deep discharge and cell balancing initiative is
applied to revive nickel cadmium and nickel metal hydride batteries;
a conditioning cycle is performed on lead acid and lithium-ion
battery types
- Test DC - Battery is Discharged, Charged
- Test DCD - Battery is Discharged, Charged, Discharged
- Test DCDC - Battery is Discharged, Charged, Discharged, Charged
- Test CD - Battery is Charged, Discharged
- Test CDC - Battery is Charged, Discharged, Charged
- Test CDCD - Battery is Charged, Discharged, Charged, Discharged
| Volt Meter Resolution |
1mV/step, 0 to 51,673mV |
| Volt Meter Error |
Greater of +/- 10mV or +/- 0.1% |
| Current Resolution |
10mA/step, 0 to 10,000mA, applies to both charge and discharge modes of operation |
| Current Error |
Greater of +/- 10mA or +/- 0.5% |
| Battery Voltage Range |
NiCd & NiMH 1-30 cells; lead acid 1-18 cells; lithium ion all types
1-11 cells except LiFePO4 1-12 cells |
| Battery Capacity Range |
300mAh to 100Ah; 100Ah capacity de-rated for batteries above
12-16 Volts nominal, limited by power and C/10 = 10A |
| Charge Power (continuous) |
200 Watts via any single channel or 200 Watts via sum of channels |
| Discharge Power (continuous) |
200 Watts via any single channel or 200 Watts via sum of channels |
| Chemistries Serviced |
Nickel cadmium, nickel metal hydride, lead acid, lithium ion |
| Lithium Ion Types (cathode) |
Cobalt oxide, iron phosphate, manganese oxide,
nickel-cobalt-manganese, plus new cathode
materials when available |
| Temperature Range/Resolution |
-30 to +90 degrees Celsius with 0.1 degree resolution; Accepts 1-100k nominal thermistor
values; Ideal value 10k |
| Temperature Recording |
0-60 degrees Celsius by 1 degree C/step, or -30 to +90 degrees
Celsius by 2 degrees C/step |
| Charge Methods |
Nickel batteries - constant current; lead acid and lithium ion
batteries - constant voltage with current limit |
| Discharge Methods |
Constant current, constant power, constant resistance, pulsed
constant current 2-5 steps |
| Pulse Discharge Range/Slew |
500us-10ms in 500us/step, 10-60,000ms in 1ms/step, Discharge current
slew rate 15Amps/ms |
| High Speed Data Logging |
500us/point or 2k points/sec, Select 1mV or 50mV
resolution,
Log snapshot or continuous(5 min max), Digital smoothing |
| Full Charge Detection |
Voltage inflection, negative delta V, input capacity, peak
voltage, waning current (lead acid & lithium ion) |
| Maximum Channels |
432 channels via a single USB host controller by connecting 108 analyzers using 19 seven port hubs |
| Enclosure |
Heavy duty aluminum enclosure with powder coat finish, available in
five colours |
| Dimensions |
Imperial : LxWxH 10.50x9.30x2.75inches
Metric :
LxWxH 267x236x70mm |
| Weight |
12lbs / 5.5kg |
| Input Connection |
3 wire AC input with third wire earth ground connection |
| Input Voltage |
Universal AC operation from 90-260VAC, 50-60Hz |
| Input Power |
250 Watts maximum at 90VAC |
| Input Fuse |
4 Amp 5x20 mm |
| System Requirements |
Windows 98, 2000, XP or Vista operating system with USB 2.0 full
speed support |
| Warranty |
1 year against defective parts and manufacturing |
Screen shot of Main PCBA Window
Screen shot of Configuration Window

Screen shot of Monitor Window

|