Battery Analyzer – Single Channel

Single Battery Analyzer Cycler Tester

2406 Battery Analyzer

Single Channel Battery Analyzer

The 2406 single channel battery analyzer / battery tester can determine the condition and capacity of your rechargeable batteries and maximize the life of your nickel cadmium and nickel metal hydride chemistries.

Buy Now!

Product Features & Specifications

Description

The 2406 single channel battery analyzer / battery tester can determine the condition and capacity of your rechargeable batteries and maximize the life of your nickel cadmium and nickel metal hydride chemistries.

User Manual and Specifications: 2406A Instruction Manual

Features

  • Wide application for testing all types of rechargeable batteries such as NiCd, NiMH, SLA and Lithium ion. The analyzer’s software can be upgraded to accommodate new battery technologies as they emerge.
  • Highly effective reconditioner for NiCd batteries. The renew function dissolves crystalline formations formed by low rate chargers and balances the cells within the pack to maximize its capacity and prevent cell reversal.
  • Quick test feature is especially useful to users who need to know the relative condition of a battery within 2 to 12 minutes. The quick test performs a series of short load tests and charge cycles to determine whether a battery is good or bad.
  • Advanced charge algorithms for each chemistry assure complete and rapid charging without overcharge. Damaged batteries are identified immediately.
  • Extensive range for batteries from 250 mAh to 60 Ah in capacity, from 1.2 – 16 Volts in voltage.
  • Stores test results of capacity and average discharge voltage for two batteries. Capacities are shown in percent format for easy reading.

Specifications

Battery Types Services NiCd, NiMH, Lithium-Ion and SLA type chemistries
Output Power 140 Watts
Output Voltage 0 – 24 Volts
Output Current 0 – 6.375 Amps
Discharge Power 140 Watts
Discharge Voltage 2.0 – 16 Volts
Discharge Current 0 – 6.375 Amps
Accuracy +/- 0.5%
Indicators Power/Off Charge/Discharge Pass/Fail Done/Working
Charge Methods For NiCd and NiMH batteries – Constant Current with multiple redundant full charge detection. For Lithium-Ion and SLA batteries – Constant Voltage with current limit
Power Requirement 120 VAC, 60 Hz, 3 Amps max. Note : This unit does not incorporate world wide AC input
Operating Temperature Recommended 10 to 40 degrees Celsius
Size 9.5 x 8.4 x 2.6 inches, L x W x H
Weight Approximately 8.0 lbs
Case Material Heavy 0.060″ aluminum with black anodized finish
Connections Detachable AC power cord and XLR output connector with alligator clip leads are included with purchase
Warranty 1 year against defective parts and workmanship

Start Analyzing with the 2406 Single Channel Battery Analyzer